page 1
page 2
page 3
page 4
page 5
page 6
page 7
page 8
page 9
page 10
page 11
page 12
page 13
page 14
page 15
page 16
page 17
page 18
page 19
page 20
page 21
page 22
page 23
page 24
page 25
page 26
page 27
page 28
page 29
page 30
page 31
page 32
page 33
page 34
page 35
page 36
page 37
page 38
page 39
page 40
page 41
page 42
page 43
page 44
page 45
page 46
page 47
page 48
page 49
page 50
page 51
page 52
page 53
page 54
page 55
page 56

Cryogenics & Magnetics15Speci!cations Temperature range 3 - 350 K Temperature stability less than 10 mK (peak to peak) Vibration stability less than 5 nm (peak to peak) Sample space 53 mm diameter by 40 mm height Sample mounting Sample in vacuum. Microscopy/spectroscopy sample mount included Electrical access 29 electrical feedthrough mini-connector terminations near sample + 9 via DV9 plug Computer control Fully automated cooldown, warmup, temperature control and more User interface Control via Windows based software on mini-computer or LabView Optical access Five optical ports (six optional), each with interchangeable radiation-blocking cold windows !bre feedthrough availableNew Cryostation - Magneto Optic OptionWe've taken the standard Cryostation, with all it's stability, and added a 1 Tesla magnetic !eld with incredible optical access and experiment "exibility. Optical access through the poles, high NA access from the sides, and low working distance access from the top make demanding magneto-optic applications simple to setup. Nano-positioning of the sample is possible inside the magnetic !eld to make this an even more powerful product!Magnet Sample

Cryogenics & Magnetics16www.lotoriel.co.ukCryostatsHPD CryosatsHPD offers a large variety of cryostats which can be con!gured individually. Depending on the required temperature and cooling power, different combinations of cryostats like pulse tube , ADR, or dilution refrigerator may be chosen. Also the integration of various contacting possibilities like electrical feedthroughs, microwave conductors or !bres is offered.Several experiments can be installed at the same time at different temperature stages of the$cryostat.Cryostat Types????????Adiabatic Demagnetisation Refrigerator (ADR)????????Pulse tube coolers????????Wet and dry dilution refrigerators????????Compatible with Janis or Leiden DR insertsModel Number101102103104105106Name MATTERHORN DENALI RAINIER OLYMPUS ANNAPURNA SHASTA Vacuum Jacket Size 21.3" Diameter 46.9" Tall 13" X 8.7" 25.9" Tall 13.9" Diameter 27.1" Tall 21.7" Diameter 43.2" Tall 21.7" Diameter 43.2" Tall 17.3" Diameter 25.6" Tall Experimental Volume 16.5" Diameter 7.6" Tall 9.5" X 6" X 5.5" 10.2" Diameter 10" Tall 17.4" Diameter 23.7" Tall 16.5" Diameter 7.6" Tall 13.3" Diameter 8.1" Tall 1st Stage Pulse Tube Cooling Power NA 25 W @ 55 K 25 W @ 55 K 35 W @ 45 K 40$W @ 45 K 40 W @ 45 K 25 W @ 55 K 35 W @ 45 K 40 W @ 45K 2nd Stage Pulse Tube Cooling Power NA 0.7 W @ 4.2 K 0.7 W @ 4.2 K 1 W @ 4.2 K 1.5 W @ 4.2 K 1.5 W @ 4.2 K 0.7 W @ 4.2K 1.5 W @ 4.2 K 1 W @ 4.2 K